Maverick Tactical / Laboratory testing

HG2 armor.
See the data.

Review the documented results behind our HG2 soft armor. Explore the shot data for three ammunition types, or read the complete testing booklet with the original laboratory reports.

Tested January 17, 2025Element U.S. Space & Defense - Belcamp

Cover of the Maverick HG2 official testing booklet
LABORATORY TEST DOCUMENTATIONJAN / 2025
20Recorded
impacts
3Soft armor
test samples
0Penetrations
recorded

The results

Three ammunition types.
Every impact documented.

Three samples tested under ambient conditions. Expand each result to see the individual velocities, deformation measurements and impact angles.

01

.44 Magnum

240-grain SJHP · Speer

7 impacts · No penetration recorded

Recorded velocity range
1,410-1,438 ft/s
Max. recorded deformation
37.0 mm
View all 7 shot results
Penetration recorded: None on every listed impact.
ShotAvg. velocity
(ft/s)
Deformation
(mm)
Obliquity
(degrees)
11,43837.00
21,42933.90
31,43336.20
4 *1,425Not recorded45
51,427Not recorded30
61,410Not recorded45
71,431Not recorded0

* Shot 4 is identified as a neckline shot in the lab report. “Not recorded” represents a blank deformation cell in the original report.

Original lab sheet · booklet page 7 (opens a new tab)
02

9mm

124-grain FMJ · Remington

7 impacts · No penetration recorded

Recorded velocity range
1,464-1,483 ft/s
Max. recorded deformation
33.0 mm
View all 7 shot results
Penetration recorded: None on every listed impact.
ShotAvg. velocity
(ft/s)
Deformation
(mm)
Obliquity
(degrees)
11,46933.00
21,47327.40
31,48330.70
4 *1,477Not recorded45
51,466Not recorded30
61,480Not recorded45
71,464Not recorded0

* Shot 4 is identified as a neckline shot in the lab report. “Not recorded” represents a blank deformation cell in the original report.

Original lab sheet · booklet page 8 (opens a new tab)
03

5.7 x 28mm

40-grain SS197SR · FNH USA

6 impacts · No penetration recorded

Recorded velocity range
1,770-1,819 ft/s
Max. recorded deformation
19.9 mm
View all 6 shot results
Penetration recorded: None on every listed impact.
ShotAvg. velocity
(ft/s)
Deformation
(mm)
Obliquity
(degrees)
11,77419.90
21,77019.40
31,81919.20
41,815Not recorded30
51,813Not recorded45
61,816Not recorded0

Results shown are specific to the listed 40-grain SS197SR ammunition. “Not recorded” represents a blank deformation cell in the original report.

Original lab sheet · booklet page 9 (opens a new tab)

Source: Element U.S. Space & Defense - Belcamp, project PH00014135, January 17, 2025. Velocity ranges use the minimum and maximum entries in the lab’s “Avg. Vel.” column. Deformation maxima use the three measurements recorded for each sample.

Read the full documentation

The complete booklet.
The original lab data.

Nine pages of testing summaries, individual shot results and the original laboratory data sheets, together in one PDF.

View / download PDF (opens a new tab)9 pages · PDF · No signup required

Understanding the report

A closer look
at the measurements.

What does “no penetration recorded” mean?

The laboratory entered “None” in the penetration column for each of the 20 listed impacts. These results apply to the samples, ammunition and conditions documented in the supplied reports.

What does the deformation measurement show?

The lab sheets record deformation in millimeters using clay backing. Deformation is listed separately from penetration. Three deformation measurements appear on each sample’s sheet; the remaining cells are blank and shown here as “Not recorded.”

Does the 5.7 result apply to every 5.7 round?

The supplied 5.7 x 28mm result is specific to 40-grain SS197SR ammunition. The report does not document testing of every load in that caliber.

What testing procedures are listed?

The laboratory sheets list “NIJ-STD-0101.07 Level HG2 (Modified)” and “Customer Request.” The source package is labeled “Preliminary Data.” The original pages are included in the booklet for review.

Report scope. These reports document independent laboratory testing using NIJ-STD-0101.07 Level HG2 (Modified) procedures. NIJ certification is not established by these reports alone.

Source status: Preliminary Data. This webpage summarizes the supplied laboratory records; the original sheets are included in the testing booklet.